DIARY: November 26, 1991 08:00 AM Tuesday; Rod Welch

Meeting with DNRC Dep Director re hiring new Engineer.

1...Summary/Objective


..............
Click here to comment!

CONTACTS 
0201 - Dep Natrl Rscrs & Consvn           406 444 6699 fax 6721
020101 - Mr. Wayne Wetzel
020102 - Mr. Walt Anderson; Hydro Power Section Supervisor; Engineering Division

SUBJECTS
Voith Contract Closeout
Solicit Engineer proposals
Scope Statement

0605 -    ..
0606 - Summary/Objective
0607 -
060701 - The purpose of this meeting is to assist Wayne in developing an
060702 - explanation for prospective Engineers for the solicitation DNRC is
060703 - making to get proposals on closing out Broadwater Dam.
060704 -
0608 -
0609 -
0610 - Solicitation proposal
0611 -
061101 - I suggested Wayne follow the ideas presented yesterday in the meeting
061102 - with the Director, ref SDS
061103 -
061104 -
061105 -
0612 -

SUBJECTS
Voith Contract Closeout
Planning, CPM

0705 - Summary
0706 -
070601 - I asked Walt when he expects to get the CPM finalized.  He said there
070602 - are some staff people in DNRC who have Macs that can create a final
070603 - graphical presentation of the CPM options we developed yesterday.
070604 -
070605 - Wayne will get one of these in large scale and Walt should have one
070606 - for the Engineering section.  This thing should be sent to prospective
070607 - engineering firms for consideration in taking over the project.
070608 -
070609 - Walt will get this done in time to include a version with the decision
070610 - to fire Tudor.
070611 -
070612 -
0707 -
0708 - 1050 called Wayne and Walt
0709 -
070901 - They were meeting in Wayne's office.  I suggested that the CPM's Walt
070902 - is getting finalized should include the lost revenue curve Wayne
070903 - sketched yesterday as the decision criteria on showing the importance
070904 - of acting quickly to mitigate damages to the Department.
070905 -
070906 - Suggested DNRC try to develop a single drawing showing the revenue
070907 - curve, and the alternate correction CPM's, one for repair of the gear
070908 - set and another replacement of the speed increaser.  It they will not
070909 - fit on one drawing, then do two drawings each with the revenue curve.
070910 -
070911 - Walt will try to get actual flow data to convert to dollars.
070912 -
070913 -
070914 -
070915 -
070916 -
070917 -
070918 -
070919 -
0710 -
Distribution. . . . See "CONTACTS"